Maintenance and Ease of Use 
    Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration 
    Simplified preventative maintenance with removable panels and fast ceramics replacement 
    7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs 
    Able to be installed on most manufacturers GCs 
    All routine maintenance, including GC column replacement, can be achieved without shutting down the system 
 
    Excellent long-term stability and equimolarity 
    Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace 
    Integrated filters to purify incoming gases boosting data integrity 
    Standalone automated pressure and leak check to guarantee leak-free performance 
    For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need 
 
Turnkey Solutions 
    ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence 
    ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection 
    ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection 
    ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection 
    Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more 
 
 The SeNSe2  is the latest development by AC Analytical  Controls. The Sulphur Chemiluminescence Detector (SCD) provides the best  sensitivity, best baseline stability and best equimolarity results, and  as such it will flexibly fit with most chromatographic solutions. 
Maintenance and Ease of Use 
    Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration 
    Simplified preventative maintenance with removable panels and fast ceramics replacement 
    7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs 
    Able to be installed on most manufacturers GCs 
    All routine maintenance, including GC column replacement, can be achieved without shutting down the system 
 
    Excellent long-term stability and equimolarity 
    Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace 
    Integrated filters to purify incoming gases boosting data integrity 
    Standalone automated pressure and leak check to guarantee leak-free performance 
    For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need 
 
Turnkey Solutions 
    ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence 
    ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection 
    ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection 
    ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection 
    Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more