OptiFPP: Cold Filter Plugging Point

Easy, Accurate, and Reliable Cold Filter Plugging Point Determination

State-of-the-Art Solution

Designed to increase the laboratory productivity through automation, the ISL OptiFPP measures the Cold Filter Plugging Point of diesel fuels completely unattended, therefore reducing the operator time but also improving greatly the analysis performance.

Product Overview

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument. The ISL OptiFPP analyzer provides automated CFPP test in strict accordance to ASTM D6371, EN 116 and EN 16329 conditions. OptiFPP precisely controls jacket cooling and electronically controlled vacuum adjusts as the test specimen is drawn though a mesh filter, per method conditions. Once crystal formation inhibits sample flow within a set time, a CFPP value is detected, displayed and stored to memory. Detailed reports are available, showing any abnormal points, as well as sample temperature behavior during the test.

The Cloud Point Kit is available with a stainless steel and a glass temperature sensor. A complete measuring head with a probe, filter unit and pipet is also available for purchase.

Key Features

1

Compact Design with Built-in Cooling System

2

Fully self-contained cooling system

3

Real-time display of test progress and results

4

Stand-alone and/or PC controlled operation

Specs

Test Methods & Precision

Standard Test Methods:
Freeze Point: ASTM D5972 (IP 435), SH/T 0770-2015, GOST 52332, ASTM D2386 (IP 16/ISO 3013) equivalent or better
Kinematic Viscosity: ASTM D7945 @ -20°C, @ -40°C and @ 12cSt, ASTM D445 (IP 71/ISO 3104) equivalent or better
Density: ASTM D7777, ASTM D4052 (IP 365/ISO 12185) @ 15°C correlation

Repeatability & Reproducibility:
Freezing Point: Repeatability: 0.5 ºC Reproducibility: 0.8 ºC

Kinematic Viscosity:
Repeatability: 0.011cSt @ -20°C, 0.021cSt @ -20°C, 0.0018 X1.4 cSt @ -40°C, 0.0021 X1.4 cSt @ -40°C
Reproducibility: 0.021cSt @ -20°C, 0.0021 X1.4 cSt @ -40°C, 0.17°C @ 12cSt

Density:
Repeatability: 0.006081 (1000 – x) kg/m3
Reproducibility: 0.008545 (1000 – x) kg/m3

Bias: 0 (relative to ASTM manual methods)

Operation

Detection: Diffusive Light Scattering (DLS) technology for freeze point. Horizontal capillary with motive force for viscosity

Cooling System: Integrated Peltier device cooling system Linear cooling profiles according to freeze point test method

System Cleaning: Automatic flush cycle, no solvent required

Application Range

Freeze Point Temperature Range: Sample: – 80 to +70°C °C or °F (user selectable)

Test Resolution: 0.1°C

Measurements

Sample Size: 0.15 mL required for test minimum, 20 mL including cleaning

Test Duration: Freeze Point & Density combined: 8 to 10 minutes Viscosity & Density combined: 10 minutes Freeze, Viscosity & Density combined: 15 minutes

Required Operator Time : 0.25 minutes

Documentation

Printing Label printer: Detailed test report in °C or °F with date & time stamped, sample information, test mode

Full-size printer: Detailed detection curve tracking of fuel behaviors during the test; can be printed as part of test report.

Internal Memory: Storage up to 5000 test runs

QC-Functions: Automatic QC-sample handling and QC-Chart

Interface

Display: Full-color, touch-sensitive, 15” high-resolution LCD screen with virtual keyboard. Languages: English, Chinese

Printer: USB interface for label printer or full-size HP/PCL printer

LIMS interface: Ethernet or RS232, Automatic LIMS transfer

Data Export: USB Memory Stick, Import into Excel

Password Protection: Different access levels for Operator, Manager, Service

Diagnostics: Automatic diagnostic functions

Accessories: Barcode Reader, label printer

Utility Requirements

Electrical: 90V to 260 VAC; 47-63Hz; 350W

Ambient Conditions: Temperature: max. 10° to 30°C; extremes not recommended

Dimensions: 54.6 cm (21.5”) deep x 33.7 cm (13.25”) wide x 44.5 cm (17.5”) high

Weight Unit: 24 kg (53 lb.) Boxed: 28 kg (62 lb.)