NSure: Nitrogen & Sulfur

Safe and Reliable Online Nitrogen and Sulfur Analysis

Determine Total Sulfur and Total Nitrogen in a Single Analyzer

Product Overview

NSure is our next-generation total sulfur and total nitrogen analyzer offering reliable and repeatable measurements over a wide range, even during process swings and ensures tight correlation with primary test methods. NSure’s updated technology guarantees ease of use and maintenance.

This innovative process solutions for gas, LPG, and liquid samples is ideal for online monitoring of blending and refinery operations, as well as petrochemical, wastewater and emissions monitoring.

PAC Powered by Antek’s NSure is built on over 40 years of expertise in elemental analysis.

Key Features

1

Meet sulfur regulations and control your process with continuous measurements

2

Achieve precise measurements with correlation to primary test methods

3

Complete combustion of sample allows for fast response even in process

4

Innovative design can operate over a wide range and withstand process swings

Specs

Detection Method

NSure Sulfur: UV- Fluorescence (UVF) Spectrometry
NSure Nitrogen: Chemiluminescence detection (CLD)

Method Correlation

NSure Sulfur: ASTM D5453, ASTM D6667, ASTM D7183, ISO 20846(SH/T0689,GB/T 11060.8 in China)
NSure Nitrogen: ASTM D4629, ASTM D5176, ASTM D5762, ASTM D7184, DIN 38409

Certifications / Area Classifications

CSA/UL, NEC Class 1 Division 2 Groups A, B, C and D
ATEX:

  • Zone 1 Ex db ib pxb IIC T4 Gb (T3 w/heated valve)
  • Zone 2 Ex db nA pxb IIC T4 Gb (T3 w/heated valve)

Range

Sulfur:

  • Full-scale ranges from 0-1 ppm/wt to 0–5% level (field adjustable)

Nitrogen:

  • Full-scale ranges from 0-1 ppm/wt to 0–2000 ppm/wt level (field adjustable)
  • Note: Higher ranges available, consult factory. Dual ranges with DCS remote selectable
    or automatic range switching.

Streams

Single or Dual stream options

Ultra-Low Detection (LLD)

100 ppb

Instrument Unit

ppm (mg/m3 is optional, users need to provide relevant parameters as required)

Repeatability

Within <0.5% of full scale, for most applications

Response Time

1 minute per stream

Analysis Time

1-5 minutes per stream (application dependent)

Noise

Less than 1% of full scale

Zero / Span Drift

1% of full scale per week

Calibration / Validation

Automatic or manual system validation and calibration with user-defined parameters

Calibration / Validation Time

1 minute per stream (application dependent)

Communication Outputs

4-20mA (active) isolated outputs, range selectable
Discrete digital inputs and outputs for remote control and status indicationRS-485 for Modbus RTU (standard)
Modbus TCP/IP and Ethernet (standard)
Remote workstation (optional)

Automatic Diagnosis

Yes

Supply and Connections

Carrier Gas: Argon, instrument air* or nitrogen (99.975%) regulated to 50 psig (3.4 Bar) at 1-15 cc/min (typical; application dependent)

Combustion Gas: Instrument air* or oxygen O2 (99.975%) regulated to 50 psig (3.4 Bar) at 350-500 cc/min (typical; application dependent)

Valve and Pneumatic Air Supply: Clean, dry, particle-free air @ 80-100 psig (5.5 – 6.9 Bar)

Purge Air Supply: Clean, dry, particle-free air at 80-120 psig (5.5 – 6.9 Bar); 425 LPM (15 SCFM) for startup and then 130 LPM (4.6 SCFM) for normal operation

*Instrument air: Clean, dry, particle-free

Note: NSure Sulfur can be operated on 100% instrument air for most applications

Sample Conditions (without Sample Conditioning System)

Sample Phase: Gas or Liquid

Sample Inlet Pressure: Up to 400 psig (27.6 Bar) (application dependent)

Sample Inlet Temperature: Up to 212˚F (100˚C)

Sample Condition: Sample should be filtered to at least 0.5 microns

Sample Return Pressure: <10-20 psi input (0.7 – 1.4 Bar); maintain ≥25 psi (1.7 Bar) differential to return to process

Voltage / Current / Frequency

115 VAC (13 Amps) or 230 VAC (6.5 Amps); 50-60 Hz

Power

1500 Watts

Display

LCD: PLC with 7” (17.8 cm) touchscreen display or 15” (38.1 cm) touchscreen display
The touchscreen is used to program the unit and display current and historical analyser results and alarm status

Operating Temperature

32-105˚F (0-40˚C), extreme conditions may require vortec cooler option

Analyzer Dimensions

Enclosures: Width – 26 in (66 cm), Depth – 17 in (43.2 cm), Height – 45 in (114.3 cm)
Floor to analyzer (minimum): 18 in (23 cm); Add 5 inches to height for Bebco Vent
Unobstructed-Mounted Enclosure: Width – 26 in (66.04 cm); Depth – 30 in (76.2 cm), Height – 72 in (182.9 cm)

Analyzer Weight

400 pounds (181.4 Kg)

Crated Dimensions and Weight

86 in (218.4 cm) x 42 in (106.7 cm) x 56 in (142.2 cm); 775 lbs. (351.5 Kg)

Configuration

NSure Sulfur: UV- Fluorescence (UVF) Spectrometry

NSure Nitrogen: Chemiluminescence Detection (CLND)

Documentation

Title Description PDF
Brochure NSure Brochure (US) Download
Brochure Maintenance Kit Download
Poster Optimization to Meet Sulfur and Nitrogen Regulations Download
Application Notes Monitoring S and N in High Viscosity Products Download
Application Notes Continuous Monitoring of Total Sulfur in Diesel Download
Application Notes Distillation and Sulfur Analysis in Gasoline Blender Download
Application Notes Diesel Naphtha Under 1ppm Download
img img img img check